Boiler stopped working, or making a noise it never used to? Most faults come down to a short list of causes. Below are the eight you’re most likely to meet, what you can safely check yourself and the point where it’s time to call a Gas Safe engineer.
One rule before we start: anything involving the gas supply, the sealed casing or the flue is for a registered engineer only. The checks below don’t need a screwdriver.
1. No heating or no hot water
Start with the basics: is the programmer on, the thermostat set higher than the room, and the boiler showing a fault code? If the boiler runs but the radiators stay cold, the cause is often a stuck diverter valve, a failed pump or sludge in the system. Those are engineer jobs. Our guide on what to do when your boiler stops working has the full checklist.
Need a Gas Safe engineer?
Callouts across Central and West London. Free quote, no call-out charge.
2. Low boiler pressure
A cold reading below about 1 bar will often stop the boiler firing. Topping it up with the filling loop is a normal homeowner task, and how to reset boiler pressure shows the steps. If it drops again within days, something is wrong. See what causes low boiler pressure for the usual suspects: a small leak, a tired expansion vessel or a weeping pressure relief valve.
3. Banging, whistling or gurgling (kettling)
Limescale or sludge on the heat exchanger makes water boil in pockets, and the boiler sounds like a kettle about to go. Left alone it shortens the life of the boiler. A power flush or a heat exchanger clean usually fixes it. Air in the system makes gurgling noises, and bleeding the radiators often helps. We explain this in how to bleed radiators properly.
4. Water leaking from the boiler
Dripping from the pressure relief pipe, a corroded joint or a failed seal all look similar from the outside. Switch the boiler off, put a bowl underneath and call us. Don’t ignore a slow drip: how to spot boiler leaks early saves a lot of damage.
5. Pilot light out or boiler won’t ignite
On older boilers a pilot that keeps going out points to a faulty thermocouple or a draught. On newer boilers the same symptom often means a failed ignition lead, a gas supply problem or a blocked condensate pipe. Don’t keep pressing reset. If you can smell gas, leave the property and follow our advice on gas leak signs at home.
6. Frozen condensate pipe
In cold snaps the plastic drain pipe from a condensing boiler can freeze and lock the boiler out. Gently pour warm water over the frozen section, then reset the boiler once. If it freezes every winter, the pipe route probably needs changing or lagging.
7. Radiators cold at the bottom, or cold spots
Cold at the top usually means trapped air. Cold at the bottom with a hot top points to sludge. Either way the boiler works harder than it should. Bleed first, and if it doesn’t help, the system needs cleaning.
8. Boiler turns itself off
Overheating, a faulty thermostat, low flow because of a failing pump or a blocked filter will all trip the boiler. A one-off is fine. Repeated lockouts need diagnosing, not resetting.
A typical example
Picture a boiler that needs topping up to 1.2 bar once a month. Each time it works, so it feels like a small chore rather than a fault. Over a winter that habit usually hides either a slow leak or an expansion vessel that has lost its charge. The pattern to watch for is not low pressure on its own, but low pressure that keeps coming back. If you want brand-specific faults, see our vaillant boiler problems Chelsea guide.
When to call an engineer straight away
- You smell gas or your carbon monoxide alarm sounds
- Water is leaking near electrics
- The boiler is giving off fumes, soot or a burning smell
- The same fault keeps coming back
For urgent cases, see emergency boiler repair london. If your boiler is old and the repairs are adding up, read boiler repair or replacement before spending more. A yearly boiler service london is the best defence against most of the faults on this page.
Boiler playing up? Call 020 7183 4810 or book a visit online. A Gas Safe registered engineer will diagnose the fault and quote before any work starts.
Common boiler problems: quick answers
What is the most common boiler problem?
Low pressure and no heating or hot water come up most often, usually through a leak, a failed part or a stuck valve.
Can I fix boiler problems myself?
You can check the pressure, bleed radiators and reset the boiler once. Anything inside the casing, and anything gas-related, needs a Gas Safe engineer.
How do I know if my engineer is registered?
Ask for their Gas Safe ID card and check it on the Gas Safe Register. Our page on gas safe engineer london explains how.

Peyman
CEO & Founder — Gas Safe Registered Engineer
Peyman is the founder of Olia's Plumbing & Heating, a London based team working in boiler installation and repair, central heating, gas work and emergency plumbing. He personally oversees jobs across Central and West London and writes these guides to help homeowners understand their heating systems.
- Gas Safe Registered
- Covering all of London